  1. Path: in2.uu.net!insync!usenet
  2. From: bubba@insync.net (Bill Garfield)
  3. Newsgroups: comp.dcom.modems
  4. Subject: Re: Trouble achieving 28.8 over SLC96 & SLC5 Digital Loop Carrier
  5. Date: Tue, 09 Jan 1996 22:01:54 GMT
  6. Organization: Associated Technical Consultants
  7. Message-ID: <4cuoht$hhh@drencrom.insync.net>
  8. References: <4cuk98$6lt@newsbf02.news.aol.com>
  9. Reply-To: bubba@insync.net
  10. NNTP-Posting-Host: line-210.insync.net
  11. X-Newsreader: Forte Agent .99b.112
  12.  
  13. On 9 Jan 1996 15:47:36 -0500, ftave@aol.com (Ftave) wrote:
  14.  
  15. >I am having troubles connecting at 28.8 from my home (which I just moved
  16. >into).  The computer/modem used to connect at 28.8 at my old home.  The
  17. >only difference that I can see between the two locations is that my new
  18. >telephone is being fed via a SLC96 (Subscriber Loop Carrier) system
  19. >whereas my old location was a straight copper pair into the telco central
  20. >office.  A friend of mine says that neither SLC96 nor SLC5 (a enhanced
  21. >SLC96 system) has the necessary bandwith (as stated in the V.34 protocol)
  22. >to achieve a 28.8 connection.
  23.  
  24. This has been a hotly debated issue.
  25.  
  26. But the bottom line is that I personally know of no one who is able to
  27. achieve full speed 28.8k bps performance out of their V34 modem when
  28. their phone line is provisioned via a SLC.
  29.  
  30. Most often the SLC's proving most problematic are terminated into an
  31. analog office, such as a 1A.
  32.  
  33. There is some thought that the line coding/framing used with
  34. conventional SLC implementations may be contributing to the problem.
  35. Most use D4/AMI.  The thinking is that B8ZS/ESF, if available, would
  36. improve things, but there are arguments on both sides.
  37.  
  38. If you're on a SLC I feel sorry for you.  I guess it's still better
  39. than a 36,000 ft copper loop.
  40.  
  41.  
  42. ----------------------------------------------------------------
  43. After ISDN, 28,800 makes you want to get out and push!!